Description
Cold start possible
Provides temporary battery power in the event of a power outage.
Energy meter
Indicates the actual load in kWh for users concerned about reducing their energy costs.
Eco-friendly fashion
Patent-pending operating mode that bypasses unused electrical components in good condition to achieve high efficiency without compromising safety.
High online performance
Reduces total cost of ownership, produces less heat.
Intuitive LCD interface
Provides clear, accurate information in multiple languages to configure the inverter on site using easy-to-use navigation keys.
Expected Battery Replacement Date
Dynamically reminds you of the month and year when the battery needs to be replaced to facilitate long-term maintenance planning.
Pre-installed network management card
Allows remote control and management of the inverter over a plug-and-play network.
Single group of controlled outlets
Single output group that can be controlled separately by the UPS for discrete reboot of suspended equipment and load shedding of non-critical and sequenced on/off loads.
SmartSlot
Customize your inverter's capabilities using management cards.
Temperature-compensated battery charging
Extends battery life by regulating the charging voltage based on actual battery temperature.
Availability
Battery Disconnected Notification
Warns when a battery is not available to provide backup power.
Automatic restart of loads after inverter shutdown
Automatically starts connected hardware when AC power is restored.
Automatic self-test
Battery self-test is performed periodically to ensure early detection of the need to replace a battery.
Intelligent battery management
Maximizes battery performance, life and reliability through an intelligent, precision charging process.
Temperature-compensated battery charging
Extends battery life by regulating the charging voltage based on actual battery temperature.
Automatic Voltage Regulation (AVR) by boost and clipping
Increases application availability by correcting brownouts and overvoltages without draining the battery.
Food processing
Protects connected loads from surges, spikes, lightning and other electrical disturbances.
Simplicity of management
Network manageable
Allows you to manage the inverter remotely over the network.
Serial connectivity
Allows you to manage the inverter via a serial port.
Audible alarms
Warns when the unit is on battery, when the battery is low or there is an overload.
Battery Disconnected Notification
Warns when a battery is not available to provide backup power.
LED Status Indicators
Allows you to quickly know the power and unit status using visual indicators.
USB connectivity
Provides UPS management via a USB port.
Security
Approved by a Safety Office
Ensures testing and certification of the product as safe to operate with connected loads and within the environment.
Marketing Features
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
An energy-efficient operating mode achieves an efficiency level of over 97%.
Smart-UPS was the first Energy Star certified grid-tie UPS. APC’s Intelligent Battery Management optimizes battery performance and life through intelligent, precise temperature-compensated charging. A dynamic battery replacement date indicator and automatic self-tests ensure battery reliability and alert you when a replacement is needed. Convenient, easy-to-connect, hot-swappable battery modules allow for battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted grid-tie UPS, with over 25 million units sold.
Save time with easy and convenient remote access
Network manageable via serial port, USB port or optional Ethernet port. Includes PowerChute© Business Edition software, which facilitates monitoring and control, secures operating system shutdown and offers innovative power management capabilities.
Optimized productivity with the ability to adapt to your specific application needs
An intuitive interface provides clear information and allows local UPS configurations with easy-to-use navigation keys. More than 15 different programmable settings, including controlled outlet groups, allow for application-specific settings, thresholds and notifications.
Peace of mind provided by the total reliability and compatibility of equipment from a leader
Delivers pure sine wave output, recommended by server manufacturers using active Power Factor Correction (PFC) power supplies. Agency tested and approved for safety, so you can deploy Smart-UPS with confidence that it meets or exceeds the most stringent industry standards.
Avoid costly power issues by keeping your computer hardware and data secure and available
Grid-grade power treatment protects against surges and disruptive noise. A solid-state automatic voltage regulator can boost low input voltage by 30% and step down high voltage by 12%, without any battery operation. Reliable battery backup power capability during power outages or extended system shutdowns
Ease of maintenance
Resettable circuit breakers
Allows rapid recovery after overload.
Hot-swappable batteries
Ensures continuity and quality of power supply to protected equipment during battery replacement.
Predictive failure notification
Provides early warning fault analysis functionality to proactively replace components.
User replaceable batteries
Increases uptime by allowing a trained user to perform battery upgrades and replacements, reducing repair times.
Battery Failure Notification
Provides battery fault analysis function with early warning, allowing timely preventive maintenance
Adaptability
Adjustable voltage transfer points
Maximize the life of your batteries, by increasing the input voltage threshold or by strictly controlling the output voltage.
Adjustable voltage sensitivity
Provides you with the solution to optimally and efficiently adapt your inverters to specific power supply systems or specific generator sets.
Provides temporary battery power in the event of a power outage.
Energy meter
Indicates the actual load in kWh for users concerned about reducing their energy costs.
Eco-friendly fashion
Patent-pending operating mode that bypasses unused electrical components in good condition to achieve high efficiency without compromising safety.
High online performance
Reduces total cost of ownership, produces less heat.
Intuitive LCD interface
Provides clear, accurate information in multiple languages to configure the inverter on site using easy-to-use navigation keys.
Expected Battery Replacement Date
Dynamically reminds you of the month and year when the battery needs to be replaced to facilitate long-term maintenance planning.
Pre-installed network management card
Allows remote control and management of the inverter over a plug-and-play network.
Single group of controlled outlets
Single output group that can be controlled separately by the UPS for discrete reboot of suspended equipment and load shedding of non-critical and sequenced on/off loads.
SmartSlot
Customize your inverter's capabilities using management cards.
Temperature-compensated battery charging
Extends battery life by regulating the charging voltage based on actual battery temperature.
Availability
Battery Disconnected Notification
Warns when a battery is not available to provide backup power.
Automatic restart of loads after inverter shutdown
Automatically starts connected hardware when AC power is restored.
Automatic self-test
Battery self-test is performed periodically to ensure early detection of the need to replace a battery.
Intelligent battery management
Maximizes battery performance, life and reliability through an intelligent, precision charging process.
Temperature-compensated battery charging
Extends battery life by regulating the charging voltage based on actual battery temperature.
Automatic Voltage Regulation (AVR) by boost and clipping
Increases application availability by correcting brownouts and overvoltages without draining the battery.
Food processing
Protects connected loads from surges, spikes, lightning and other electrical disturbances.
Simplicity of management
Network manageable
Allows you to manage the inverter remotely over the network.
Serial connectivity
Allows you to manage the inverter via a serial port.
Audible alarms
Warns when the unit is on battery, when the battery is low or there is an overload.
Battery Disconnected Notification
Warns when a battery is not available to provide backup power.
LED Status Indicators
Allows you to quickly know the power and unit status using visual indicators.
USB connectivity
Provides UPS management via a USB port.
Security
Approved by a Safety Office
Ensures testing and certification of the product as safe to operate with connected loads and within the environment.
Marketing Features
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
An energy-efficient operating mode achieves an efficiency level of over 97%.
Smart-UPS was the first Energy Star certified grid-tie UPS. APC’s Intelligent Battery Management optimizes battery performance and life through intelligent, precise temperature-compensated charging. A dynamic battery replacement date indicator and automatic self-tests ensure battery reliability and alert you when a replacement is needed. Convenient, easy-to-connect, hot-swappable battery modules allow for battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted grid-tie UPS, with over 25 million units sold.
Save time with easy and convenient remote access
Network manageable via serial port, USB port or optional Ethernet port. Includes PowerChute© Business Edition software, which facilitates monitoring and control, secures operating system shutdown and offers innovative power management capabilities.
Optimized productivity with the ability to adapt to your specific application needs
An intuitive interface provides clear information and allows local UPS configurations with easy-to-use navigation keys. More than 15 different programmable settings, including controlled outlet groups, allow for application-specific settings, thresholds and notifications.
Peace of mind provided by the total reliability and compatibility of equipment from a leader
Delivers pure sine wave output, recommended by server manufacturers using active Power Factor Correction (PFC) power supplies. Agency tested and approved for safety, so you can deploy Smart-UPS with confidence that it meets or exceeds the most stringent industry standards.
Avoid costly power issues by keeping your computer hardware and data secure and available
Grid-grade power treatment protects against surges and disruptive noise. A solid-state automatic voltage regulator can boost low input voltage by 30% and step down high voltage by 12%, without any battery operation. Reliable battery backup power capability during power outages or extended system shutdowns
Ease of maintenance
Resettable circuit breakers
Allows rapid recovery after overload.
Hot-swappable batteries
Ensures continuity and quality of power supply to protected equipment during battery replacement.
Predictive failure notification
Provides early warning fault analysis functionality to proactively replace components.
User replaceable batteries
Increases uptime by allowing a trained user to perform battery upgrades and replacements, reducing repair times.
Battery Failure Notification
Provides battery fault analysis function with early warning, allowing timely preventive maintenance
Adaptability
Adjustable voltage transfer points
Maximize the life of your batteries, by increasing the input voltage threshold or by strictly controlling the output voltage.
Adjustable voltage sensitivity
Provides you with the solution to optimally and efficiently adapt your inverters to specific power supply systems or specific generator sets.
Features | |
UPS Topology | Line interactivity |
output power capacity | 2.2 kVA |
Output power | 1980 W |
Waveform | Sinus |
Input voltage voltage (min) | 151 V |
Input voltage voltage (max) | 302 V |
Input frequency | 50/60 Hz |
output voltage voltage (min) | 220 V |
Output voltage (max) | 240 V |
output frequency | 50/60 Hz |
Energy Surge Estimation | 375 J |
Response time | 4 ms |
Emergency Power Cut Off (EPO) button | O |
Sound level | 55 dB |
Surge Protection | Yes |
Audible alarms | Yes |
Web-based management | Yes |
Sound Alarm Modes | Battery replacement |
Automatic restart | Yes |
Connectivity | |
AC Output Types | C20 coupler |
Male plug | C20 coupler |
Number of output sockets | 9 AC output(s) |
Quantity of USB 2.0 Ports | 1 |
Number of LAN ethernet ports (RJ-45) | 1 |
Battery | |
Battery technology | Sealed Lead Acid (VRLA) |
Battery capacity | 509 Ah |
Battery recharge time | 5 a.m. |
Hot-swappable battery | Yes |
Automatic battery test | Yes |
Cold start | Yes |
Design | |
Format | To put on rack |
Product color | Black |
Rack capacity | 2U |
Screen type | LCD |
Seers | Yes |
Certification | CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2, GS Mark, IRAM, RCM, VDE, WEEE |
Environmental conditions | |
Operating temperature | 0 - 40 °C |
Non-operating temperature | -15 - 45 °C |
Operating relative humidity (HH) | 0 - 95% |
Relative humidity level (storage) | 0 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Technical details | |
Sustainability certificates | Green Premium, RoHS |
Weight and dimensions | |
Width | 480 mm |
Depth | 683 mm |
Height | 86 mm |
Weight | 42.2 kg |
Package width | 600 mm |
Package depth | 980 mm |
Package height | 254 mm |
Package weight | 49.6 kg |
Packaging information | |
Rack mounting kit | Yes |
Cables included | Input cable, USB cable |
Quick Installation Guide | Yes |
Resource CD | Yes |
Logistics data | |
Products per pallet | 8 room(s) |
Harmonized System Code | 85078000 |
Other features | |
Output voltage | 230 V |